Configuration of the Auto-save Function-HUAWEI

********The Auto-save Function-GPON********

To enable auto-save at preset interval on the MA5600T, set the auto-save interval to two day (2880 minutes), and save both the database file and the configuration file, do as follows:

OLT(config)#autosave interval on
OLT(config)#autosave interval 2880
OLT(config)#autosave type all
OLT(config)#save

                                     ********END********