Configuring the NE Subtending Through the FE or GE Port-HUAWEI

******NE Subtending Through the FE or GE Port******

Assume that master NE OLT_1 and slave NE OLT_2 are subtended through the GIU board. To add upstream port 0/19/0 and subtending port 0/19/1 of OLT_1 to VLAN 100, and add upstream port 0/19/0 of OLT_2 to VLAN 100, do as follows:

OLT_1(config)#vlan 100 smart
OLT_1(config)#port vlan 100 0/19 0
OLT_1(config)#port vlan 100 0/19 1

OLT_2(config)#vlan 100 smart
OLT_2(config)#port vlan 100 0/19 0

Assume that master NE OLT_1 and slave NE OLT_2 are subtended through the ETHB board. To add upstream port 0/19/0 and subtending port 0/6/0 of OLT_1 to VLAN 100, and add upstream port 0/19/0 of OLT_2 to VLAN 100, do as follows:

OLT_1(config)#vlan 100 smart
OLT_1(config)#port vlan 100 0/19 0
OLT_1(config)#port vlan 100 0/6 0
OLT_1(config)#interface eth 0/6
OLT_1(config-if-eth-0/6)#network-role cascade
OLT_1(config-if-eth-0/6)#quit

OLT_2(config)#vlan 100 smart
OLT_2(config)#port vlan 100 0/19 0

                                         *****END******

Be the first to comment

Leave a Reply

Your email address will not be published.


*


For security, use of Google's reCAPTCHA service is required which is subject to the Google Privacy Policy and Terms of Use.

I agree to these terms.